Hot settings are the settings at the operatingconditions. Cold settings are the settings at the installed position orstart-up. The piston setting is the location of the position within the snubber at the cold position. Pre-set can refer to the setting specified by theengineer due to the anticipated movement.
![Hydraulic Snubber Pre-Set To The Midpoint Of The Overall Stroke Of 6' Hydraulic Snubber Pre-Set To The Midpoint Of The Overall Stroke Of 6'](/wp-content/uploads/2017/10/hydraulic-snubber-assemblies-for-a-lng-processing-facility-in-peru_5136262746_o.jpg)
Hydraulic Snubber Pre-set to the Midpoint of the Overall Stroke of 6″