Hydraulic Snubber Designed for a Gas Turbine in a Natural Gas-Fired Combined Cycle Generating Power Plant

December 14, 2014

Hydraulic Snubber Designed for a Gas Turbine in a Natural Gas-Fired Combined Cycle Generating Power Plant

Fronek Anchor/Darling Enterprises Inc., a division of PT&P designed and fabricated this hydraulic snubber assembly for a gas turbine in a natural gas-fired combined cycle generating power plant in Pennsylvania. This fig -510AD is designed for a 10,000 lb. load and a 6″ stroke. It measures 28-1/2″ pin-to-pin and has a 2-1/2″ diameter cylinder. It is designed for an operating temperature of 1052°F and a movement of 4-1/8″. This snubber was tested using the STADAS test machine prior to shipping.