Trunnions with Micarta ® G-10 Designed for a Cryogenic Pipeline

Trunnions Designed For A Cryogenic Pipeline At An Lng Facility

Type: Trunnions for Cryogenic Temperatures
Size: 8″-24″ Dia. | 12″-18″ L | 6″-15″ W | 6″-40″ H
Material: Micarta® G-10 Insulation | CS | SS
Design: Cryogenic Temperatures of -320°F
Testing: MTR’s | Non Destriuctive (PMI) | Q.C.

PT&P custom designed trunnions for a cryogenic pipeline at an LNG facility in Australia. The insulated supports were fabricated with carbon steel base plates, 304L stainless steel plates and fasteners. To prevent cryogenic temperatures of -320°F from transferring to the base of the trunnion support, Micarta® G-10 was used as insulator. The trunnions were designed to support pipe sizes from 8”-24” with dimensions ranging from 12”-18” in length, 6”-15” in width and 6”-40” in height. MTR’s were provided, and non-destructive testing (PMI) was preformed, along with standard Q.C. inspection prior to shipment.

This type of support is available in pipe sizes between 1/2″ to 42″ NPS; however, PT&P can customize any size needed. The standard material for these supports are galvanized or hot-dipped galvanized carbon steel. These supports were customized with Micarta® instead of the standard high density polyurethane with vapor barrier. When ordering, specify pipe size, insulation thickness and length. See more on Figure CS-6030 from our cryogenic pipe supports section.

Piping Technology & Products and Pipe Shields have been a major international supplier of pipe shoes and pre-insulated supports for more than 10 years. Our cryogenic pipe supports comply with the following standards ANSI / ASME B31.1 & B31.3 and The Manufacturers Standardization Society SP-58, 69, & 89.

Read More

Cryogenic Pipe Supports with Micarta® G-10 for an LNG Facility in Australia

April 16, 2018

Cryogenic Pipe Supports With Micarta® G-10 For An Lng Facility In Australia

Type: Cryogenic Pipe Supports
Size: Pipe Size of 1” to 36”
Material: LTCS Material Tops, Stainless Steel, & Micarta® G-10 Insulation
Design: -50°F
Testing: PMI

Piping Technology and Products supplied cryogenic pipe supports with axial stops for an LNG facility in Australia. The cold shoes were fabricated utilizing low temperature carbon steel, stainless steel and Micarta® G-10 insulation blocks. We supplied a wide range of lengths and pipe sizes from 1” to 36”. The cryogenic temperatures are low as -50°F. A special paint system was used for the low temperature carbon steel components to resist rust. PMI testing was performed on the stainless parts. Delivery was within 4-6 weeks.

Read More

Cryogenic Pipe Supports with Micarta® G-10 for an LNG Facility in Australia

April 16, 2018

Cryogenic Pipe Supports With Micarta® G-10 For An Lng Facility In Australia

Type: Cryogenic Pipe Supports
Size: Pipe Size of 1” to 36”
Material: LTCS Material Tops, Stainless Steel, & Micarta® G-10 Insulation
Design: -50°F
Testing: PMI

Piping Technology and Products supplied these cryogenic and axial stop cold shoes for an LNG facility in Australia. The cryogenic pipe supports were fabricated with LTCS material tops, stainless steel and Micarta® G-10 insulation blocks. They were a wide range of lengths from pipe size of 1” to 36”. The cryogenic temperatures are low as -50°F. A special paint system was used for the carbon steel components to resist rust. PMI testing was performed on the stainless parts prior to the 4-6 week shipping.